Investigate-a-defect
Brand C · PA-02Investigation context
Brand history · last 4 panels
Floor 6.0 · dashed
Defect breakdown · top 8 by weighted variation
35 more attributes hidden · weighted variation tails off below the top 8.
Step 6 — Save the investigation
Investigation into Pumpkin/ Gourd. Confirm the summary below — closing freezes the record for the Verification Brew Review (Phase 4).
Batch
Brand C · PA-02
Problem statement
Brand C PA-02. Major defect: Pumpkin/ Gourd flagged by 2 panelists.
Chains walked
Man, Method, Measurement
Confirmed root causes (3)
There is no mark on the fermenter doc for cone collected complete, brewer was unsure of the impact
asdfasdfasd
asdfasf
Committed corrective actions (3)
Man — 1 action
Training team on impacts of sitting on yeast
Method — 1 action
Add a check and signoff for cone collection on the ferm sheet
Measurement — 1 action
Add BBT CC check to verify carryover
Status · Closed
Closed on 2026-08-20. The Investigated chip on the Scan tray reflects this state immediately. Verification Brew Review ships in Phase 4.
Investigation id · 880f89b0-3d66-4cf5-8f55-c123edf05789